honeywell wv8840b1109 manual

Thanks a bunch! Isnt there any way to tell the gas valve to quit having a hissy fit and get back to work? Problem solved. Light the pilot light as normal. I also drained some water then flushed a lot. I keep flushing the tank through a short piece of hose every week or so and the water out looks pretty clean now so Ill only do it once every six months or so to keep it clean. I didnt think it would work, live and learn. Now there is no danger of releasing gas. Appreciate the guidance. Mine quit working last Wednesday (Christmas Eve), with a house full of company. Regardless what I tried, it was still 4 flashes. Never had this problem with old fashioned hot water heaters. All models of, WT8840 include an integrated NTC temperature, The WT8840 is powered from a thermopile heated by, the standing pilot flame. Keep track of which front is which! Even though there are 4 higher settings! The WT8840 Water Heater Control is designed for use in Standing Pilot applications using an immersion well for water temperature sensing. My water heater is still working fine. Once you have the pilot lit and the pilot valve on, (faint click can be heard) all that is necessary to open the main valve is to jump (connect) the top left pin to the top right pin. My Honeywell WV8860B1309 failed after 2 years. Removed the old cover and board and replaced it with the new one. This time they are sending me a new gas valve for free overnight. Ignite pilot then rotate to hot. My Family thanks you for the tip to reset the Honeywell Gas control valve. If I dont update this entry, assume it is (for now). I was told that you can use the yellow teflon and sealant for gas and water, but the water products do not work on gas. There is also a White or clear silicone rubber gasket that is entangled with pins and solenoid wires. The cover on the Water Heaters gas valve is removed by a single flat head screw at the bottom. On 21 November, 2014 I performed the fix that Charles described on 29 July, 2014. Jolie, even you can do this. They would have to diagnosis the water heater and then order the part, and then come back again to install at an additonal service price. I cant believe this actually worked!!! Say, Im going to rip you open, you dirty so-and-so. See whether the light goes back to its regular one-blink mode in response to this threat. The WT8840 is powered from a thermopile heated by the standing pilot flame. Could only see me in the eveningReading about what you guys have done. It took right off and has been working fine. Mine is 3 1/2 years old. DO NOT RECOMMEND WHIRLPOOL HOT WATER HEATERS WITH HONEYWELL GAS CONTROL VALVES! Whirlpool owners are fortunate that the company is sending them replacement valves. Using a flat tip screwdriver remove the bottom screw that holds the housing on. Turned the dial to low and it started heating. Maybe a model or serial number? DO NOT BUY THIS THERMOSTAT! heres what i did take off the cover on the valve and disconnect the 3 wire connector. This should at least get you hot water and time to get another controller from like Amazon. Will keep this for next year when it breaks again. If that didnt work, or if you already have the new valve and prefer the slightly simpler approach, proceed as follows. If one uses a slow supply of hot water (like rinsing a lot of dishes), then the heater stays on making VERY hot water until it triggers a non-resetable error. Ive tried everything trying to reset it , although it seems the flame is on . Ive been reading the above posts with great interest. This does require one special tool, pictured at left. correction on part where my friend bets me $100 its the thermo pile should have read Valve. Just for reference THISpicture shows the wire that attaches to the control board. i was still under warranty so the valve was free less $30 overnight shipping. I am trying to get an idea of how reliable the soluton is. ~ diy-home-projects.vwx.info. water heater $500-$800, pro lic installer $400 $30-$$60 shipping cost for Valve. The Right top Pin is the main gas valve. Honeywell has a scam going, I paid over $500,00 for my water heater and several hundred to have it installed, since day one I have had nothing but trouble with the Honeywell thermostat,gas valve. Should save this to a word fileBut hopefully I wont ever need them again..My water heater is 2 years old and has a 6 year warranty on parts..I called Monday morning and spoke to a Johnathon (real nice fella) and he shipped me the whole thermostat assembly. Finally this past week it was in the error mode and stayed there. It cant flip up (actually it can if you try hard enough, but then youve probably broken it). Not sure if these links will come thru, however I took a few pictures of my replacement. CORRECTING LAST SENTENCE: main valve (Right pin to (+), So I would recommend to you ( with Valve off the water heater and no gas applied, to test the pilot valve (left pin to (+))with the AA battery, and test the main valve (Right pin to (+)), and each individually should click, photo of pilot valve solenoid . This is what he had me do: If youre ever in Fort Wayne Indiana, Ill treat you to a steak dinner/sushi/(or your preference)! Oh and THISis what it looks like in the little window when your BURNERSare running (water heater is heating). I dis-assembled the cover and the circuit board, then tested the actual gas valve by itself using a AA battery and jumper wires (mentioned elsewhere above earlier) ( negative (-) to the bottom of V and positive to left upper pin of V. So I got no click (but supposed to get a click). David Boone I Love You. This is a picture of what it looks like with all the wires attached and the actual valve pins in the V formation (on the right side of the picture). After going through this ordeal, I had the pretty much the same experience as ColdShowerMan. You can only find the entire assembly. WV8840B1109 WV8840B1110 316910-000 316910-000 321166-000 100112336 & 9007884005 AO Smith AO Smith AO Smith WT8840B1500 2" insulation tank, 5" WC setting . Wish Id had it before I Paid the 30.00 shipping for the new board. (no blinks, no pilot) Turned it around and clipped it back in and went through the lighting the pilot light. Just one stinking notch! The Temperature probe is a different design. What your friend did to fix your problem temporarily, was press the reset button on the safety interlock probably located on the access cover of the heating chamber. I called my father-in-law and told him about it, he is a plumber and replaces this kind of valves all the time but he said he has never seen one that flashes any codes other than normal right out of the box Go figure!!! Just lit the pilot again and set the temperature!! I will never buy anything from Kenmore or Honeywell! This is huge the most important post. I tried the other methods to discharge the caps etc Those Methods did not work. This time I left the knob in the pilot position for 10 minutes. It is interesting to note that 106F is normally just about as hot as you can stand in the shower. After reading through everything in both Cranky and DBs posts a couple more times, finding a 9v battery and making a second jumper wire to try the battery procedure described in DBs post, I went back to the unit, turned the gas supply back on and re-lit the pilot, when BINGO! After days re-seating all the wires I found that cleaning the lint out of the cage where the main gas flex tube enters an air tunnel leading to the main burner about 6 inches below the white cover fixed it. > little white reset button doesnt seem to have any effect!?! Cheers. CS8840 pilot assemblies are designed for use with this control. i followed your instructions and bingo! For sure theyre going to have a lot of unhappy customers. For $75 theyll come out to asses. The next guy I talked to was very surprised that the Valve would be bad again so quickly so he had me go through a reset procedure. 2. Error clears. Think Ill leave my old one on till it goes out again then replace with new one. It lights easily, but wont stay lit. Holy Crap DB! THIS METHOD WORKS!!! Ive been keeping an eye on the heater ever since installing, so I was able to notice this. 5 gas rated pipe sealant. When I screw the gas adapter, just half way in the screw, the housing cracked. The entire process from start to finish, including 2 stops to Lowes (once for tools, second for piping) and draining/refilling tank took over 2 hours. The unit will go to 7 blinks initially, but the burners will kick on and after a bit will revert to 1 blink every few seconds (normal operation). Its an excellent description, and if you dont already have the new valve, I suggest you try that first. Although, it wouldnt hurt to turn the gas off at the water heater line by twisting the valve into the horizontal position. $49.89. When I put it back together, it still flashed 4 lights and only the pilot would light. The main burner would go out without being up to temp (it may of been shutting off on the high limit ?) Let me step in line with all of you. The red one, I found, CAN be reset using above methods. Put the cover back on temporarily with the connector still disconnected. Reverse the above steps to mount the new front onto the old back thats still hooked to the water heater. Pre-owned. The bottom pin is ground ((-) on the battery)Connect the (-) negative of the battery there with a clip lead. Cal. NEVER TO BE PURCHASED AGAIN. Went from four blinks to seven. I understand that the Honeywell product is in recall. I have a state water heater (which are made by A.O. I was told to flush the water heater 2xs a year with vinegar to remove sediment, which i did have ALOT..Thanks. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. Next, there are at least two variations of this unit. Thanks, wife thinks I am a genious. I am not sure if holding the temperature button in is electronic or mechanically acts on the pilot valve (would hope the latter). This worked well. So a few notes to help those that are experiencing the same thing: 1. Now, I urge CAUTION when performing this fix as, without a working pilot, you could accumulate an appreciable amount of gas and risk an explosion. Water Heater Gas Valve Replaces Honeywell Resideo WV8840B1109 WV8840B1110 WV8840B1109 WV8840B1110 Furnace Heater Gas Valve Shut-off Slow Fast Opening Pilot Spark Hot Surface Ignition Repair Part . The water heater is a Kenmore and I called Sears but they only wanted to send out a service worker for $79/$90 to diagnosis the water heater although I explained numberous times that the water heater is OK It is the controller that failed. I have the same set up as rdarnitall on 31 December 2014 at 7:28 pm and I just wanted to say thanks for that reset procedure, it worked for me. I wish I had known this a few months ago. Ive been reading through all this information, but other than learning the honeywell unit is a POS, I havent figured out my problem. The most I have had to do this is twice before the fault cleared. BTW I wouldnt try to short everything in sight to GND, because the board and components are conformally coated to seal out moisture, so you dont want to damage the coating. It installed easily. DONT BUY THEM. At just 3 months old the second unit failed! Looking for a new appliance retailer who values its customers. The pilot would stay lit for a while and then go out with a code 2 blink. Any way, the pilot fired up rather quickly and flashed one time every three seconds! Miller Air Core Oil and Gas Harness. A huge thank you to Tyler, Loreleaf and everyone who has contributed here. All that Sears tried to do was sell me a warranty extension for $199. 8: Once the status is blinking, set the temperature to desired level. As for Kenmore and Sears they would send a replacement part our for $185.00 and 2-5 days delivery or since the part is under warranty I could pay $79.00 and wait for a service appointment, then wait for the replacement part to be shipped for me to install. Feeling clean & grateful for hot water! I came home from a 10hr workday Wednesday to a cold shower! And so the very thin wires (at point where wire became tinned or soldered) became brittle and had broken. Last year I had the blinks. All models of WT8840 include an integrated NTC temperature sensor. Because, when they shop at Lowes (and other DIY stores), people dont always, every time, ask them, You carry repair parts for this, right? The battery trick worked for me. I have the exact electronic gas valve unit on my Whirlpool water heater I purchased 3 years ago. What a pile of JUNK!!! If it finds a fault, it will shutdown. I installed the new valve and cleaned up the mess. Thanks all and internet! So now it is connected up as it would be normally but without the cover attached. Thanks again to all. I then turned the gas valve to hot and it lit and ran. Ill let you know how it worked out. Rather, drain it at a slower rate with a 1K ohm resistor. In this case relight the pilot and try again. Two plastic clips at the top are holding the cover on. [] research briefly mention entertaining ? Wow it worked great. Tug gently, away from the board, to unplug the plug. One has a red mode indicator (the older one) and a white one. I did call Whirlpool and told them that the new valve they sent was broken and they did send another replacement free overnight. OMG!! A plumber I know told me he has replaced dozens of these exact same units. Started right back up. No, I dont know that you can buy just the circuit board. It has a stainless steel protective cover. By the time I returned (maybe 30 minutes later), the led had returned to its normal blue 1-flash mode. Time will tell. Yes my 20 month old envirotemp gas water (purchased from lowes) heater quit and is displaying 4 flashes of death . My new controller has a white blinking LED that will not reset. BUT, the adapter for the wire harness only goes into the new board one way. Can cause severe injury, death or property damage. BONUS!!! WV8840B1110 has been discontinued Discontinued December 15, 2019 This product was discontinued by the manufacturer. The water heater would not work properly right out of the box. I havent opened the valve yet out of curiosity but from what I read here, the Capacitor sounds like a good culprit. Looking at the V of the Valve body pins, the left top pin is the pilot valve. (PSFlushing the tank as others have posted is sound advice to), YOU, MY FRIEND, ARE A FRICKING GENIUS IT WORKES. In particular, if you havent drained the sediment off the bottom of the tank, do that first. I didnt use a battery and just jumped upper left and upper right pegs. My installation uses a tempering valve to keep water to the home closer to 110F no matter what the solar temperature is (which can be up to ~140F in summers). Honeywell stinks & has caused lots of trouble for me. I woke up on a Saturday morning to this issue and used your Fault Clear instructions and they WORKED! Association (CSA) to the following standards: Powered damper water heater controls (13 pages), Powered direct vent gas water heater (44 pages), Bathroom heater with towel rail (78 pages), Manual will be automatically added to "My Manuals", Troubleshooting with Status Light Visual Indication, Mounting the WT8840 on the Water Heater Tank, Procedure to Check the Gas Input and Burner Flow Rate, Troubleshooting Without Status Indicator Assistance, Troubleshooting Guide Without Status Light, Troubleshooting with status light visual indication, Water Heater Honeywell WV4262B Installation Instructions Manual, Water Heater Honeywell BH-777FTE User Instructions, Water Heater Honeywell VE300S Installation Instructions Manual. Wow, amazing! What powers the light? It is obvious that they are making a killing on money selling this to just about every water heater brand out there.

Steve And Geraldine Salvatore Death, Ridge Community High School Shooting, Hayman Island Ferry Timetable, Articles H

I commenti sono chiusi.